s article serves as a guide to electrical safety along to the requirements of Regulation 64 of the Workplace Health and Safety Regulations. This particular safety regulation is, of course, aimed at preventing electrical disasters. Outlined underneath are the general requirements for this safety regulation.
1. If you don't propose to use a generator, make sure that the mains power is up ahead starting construction work. Never depend on a power supply from contiguous properties since this poses numerous more problems than it does benefits.
2. One main switchboard must be present in the site. This main switchboard must be well protected and easily accessible. Furthermore, this switchboard must be placed as close as possible to road level and must be built of high-strength substance.
3. Distribution boards must be made lightly procurable. If the construction work is done on a multi-leveled architecture,[link widoczny dla zalogowanych], each class must have a delivery embark for easy access. Make it a point not to have flexible cords sprawled across levels unless this is necessitated when working in elevator shafts, stair-wells and for other work that are done simultaneously on multiple levels.
4. For mains cables that are made to run horizontally along the site, these should be supported at intervals of 3 meters and at a altitude of not less than 2 meters.
5. For chiefs wires that are made to sprint vertically, they have to be supported every 6 meters and made a special assist as the topmost point.
6. Catenary wire that are used as supernal wiring must use a double layer of insulation. If avoidable,[link widoczny dla zalogowanych], supernal wirings must not cross conveyance tracks. If this is inevitable although,[link widoczny dla zalogowanych], then a minimum supernal conductor clearance of 4 meters must be applied.5 meters must be preserved and catenary placed at a clearance of about 3.9 meters and at 6 meters at both side of the aerial conductors.
7. Having safety switches for transportable cabins, welding equipment and lighting circumferences is a must.
8. It is a must that malleable cords must not have its wrappings in the color green and that they be placed in zones where they would not be exposed to conditions that would cause them damage. They should too be made supported off the ground if they are extra than 10 meters in distance from the device they are connected to and if the cross access ways.
9. Inspection and testing must be done on every electrical equipment to be accustom in the construction go. This procedure could be thought somewhat intricate and and may absence to be studied. Also, just while a construction worker is almost to use an electrical equipment, this worker must make one ocular inspection of the electrical equipment for variant safety meter towards aversion of injuries caused at electrical shocks.
These are general requirements to strictly emulate during construction work. Studying these is extremely recommended to assure that these would be properly implemented. Making sure that 1 has taken all the steps to avoid electrical disasters is an more step towards making the construction site a safe area for one's workers. This is why abiding with Construction Safety Regulations is fussy.


Post został pochwalony 0 razy
Powrót do góry
Zobacz profil autora
Wyświetl posty z ostatnich:   
Napisz nowy temat   Odpowiedz do tematu    Forum Forum MESA !! Strona Główna -> Korona Kielce Wszystkie czasy w strefie EET (Europa)
Strona 1 z 1
   
 
Opcje 
Zezwolenia Opcje
Kto jest na Forum Możesz pisać nowe tematy
Możesz odpowiadać w tematach
Nie możesz zmieniać swoich postów
Nie możesz usuwać swoich postów
Nie możesz głosować w ankietach
Kto jest na Forum
 
Jumpbox
Kto jest na Forum
Skocz do:  


fora.pl - załóż własne forum dyskusyjne za darmo
Theme FrayCan created by spleen & Download
Powered by phpBB © 2001, 2005 phpBB Group
Regulamin