amazes me how frequently I hear people confuse MDB and DEX, as if they are related. Allow me to end that rumor right here. The only correlation between DEX and MDB is that they are two separate and distinct technologies that happen to reside in modern day vending machines.
So what is DEX?
DEX was brought to the industry in the late 1980s to provide better audit capabilities. The bottlers brought DEX, a uniform commercial code set up across many industries, to vending when they implemented DEX for communications between a route handheld and a grocery stores computer system. Since many bottler route drivers performed direct store delivery (DSD) as well as service of can/bottle machines, it made sense for their handheld to communicate with the vending machines they serviced as well as the stores.
As often happened due to their size, resources and commitment to implementing technology, the bottlers took the leadership position, and the National Automatic Merchandising Association Technology Committee (made up mostly of engineers and industry suppliers) followed suit, adopting DEX as our industry standard.
DEX is our standard for an ASCII code-based electronic audit file, a way to communicate information such as sales, cash in bill validators, coins in coin boxes,[link widoczny dla zalogowanych], sales of units by selection, pricing, door openings, and much more. It is created either locally by the VMC (Vending Machine Controller often called the brain of an electronic machine) or created by a retrofit DEX device in older electromechanical (dip switch) machines.
DEX is the result of the VMC storing information on an interval basis (the interval of time since the last DEX reading) and cumulative basis (since the VMC was first installed or the machine went into service). The VMC accumulates the data and transmits it in DEX format over the DEX port when requested.
DEX data is quite useful and extensive. It eliminates the need for route people to write what they loaded into a machine on a route card. It also makes it unnecessary to manually input this information into a handheld. But the feature of DEX that gets most companies excited and starting to DEX their machines is the accuracy of cash accountability. There is no more second guessing what was to be collected out of the machine.
DEX data is downloaded to a handheld device or transmitted via a remote monitoring device over to software that can parse the information into useful reports. DEX is downloaded using a 0.25-inch stereo plug (exactly like the one with your old stereo headphones from the 70s).
When downloaded to a handheld, DEX is parsed and compared to planogram information unique to that machine that was stored in the handheld. This informs the route driver how many units of each product he/she has to load back into the machine to bring it back up to par.
Remote monitoring devices (wireless,[link widoczny dla zalogowanych], LAN or telephone) can forward DEX, usually via the Internet, to a central computer where the software performs the same tasks as the handheld, but from the headquarters.
This gives vendors the opportunity to pre-assemble items for locations before drivers leave and efficiently pack route trucks with only the necessary products. Approximately 60 to 70 percent of the machines currently deployed have native DEX, meaning the machines come with a VMC that produces DEX.
Sometimes a newer version of firmware for the VMC and a DEX download cable are required to be added to enable DEX. Older electronic and electromechanical machines not equipped with DEX can be retrofitted with either a new VMC that provides DEX (and many of the features found in new machines) or with a retrofit DEX audit device.
Multi drop bus
MDB (multi drop bus) relates to the different payment systems interfacing together. When vending machines were electromechanical (using dip switches), bill validators and cashless systems had to run through the coin mechanisms. There were a slew of different connector


Post został pochwalony 0 razy
Powrót do góry
Zobacz profil autora
Wyświetl posty z ostatnich:   
Napisz nowy temat   Odpowiedz do tematu    Forum Forum MESA !! Strona Główna -> Wisła Kraków Wszystkie czasy w strefie EET (Europa)
Strona 1 z 1
   
 
Opcje 
Zezwolenia Opcje
Kto jest na Forum Możesz pisać nowe tematy
Możesz odpowiadać w tematach
Nie możesz zmieniać swoich postów
Nie możesz usuwać swoich postów
Nie możesz głosować w ankietach
Kto jest na Forum
 
Jumpbox
Kto jest na Forum
Skocz do:  


fora.pl - załóż własne forum dyskusyjne za darmo
Theme FrayCan created by spleen & Download
Powered by phpBB © 2001, 2005 phpBB Group
Regulamin